CONTRACTORSOFTWARE HQCompare Jobber vs Housecall Pro
Menu

Clean oil. Deep vacuum. A tidy install record.

Best HVAC vacuum pump for mini-split and residential installs

Compare five A2L-rated HVAC vacuum pumps: Fieldpiece, cordless NAVAC, Yellow Jacket and CPS. See CFM, micron ratings, oil handling, weights and job-record tips.

We may earn a commission if you buy through our links — it doesn’t change our picks. How we make money →

Product details from maker pages, checked Oct 2026.

JobberGuide

Buy the pump. Keep the evacuation result.

Choose your powerCorded supply or the cordless battery kit

Keep oil changes easyRunQuick, isolation valve or a standard oil routine

Record the holdSystem microns, elapsed time and job photos

Your decision, at a glance.

Shortlist5 exact A2L models
Flow range4–6 CFM
Bring with itMicron gauge · clean oil
Research checkedOctober 24, 2026

Our verdict

Buy the pump. Keep the evacuation result.

Start with Fieldpiece VP67 for a corded residential setup with RunQuick oil changes. Choose NAVAC NP4DLM for cordless mini-split work, Yellow Jacket 93760 for selectable voltage, CPS VPS6DU for a sparkless 6 CFM setup, or NAVAC NP5DP2 for a straightforward corded five-CFM pump. Pair the pump with a system-side micron gauge, then save the vacuum and hold result with the install.

Best corded all-rounderFieldpiece VP67
Best cordless mini-split setupNAVAC NP4DLM
Best sparkless 6 CFM pickCPS VPS6DU

A good vacuum pump earns its space in the van by making clean oil, tidy hose connections and a proper evacuation easy. For mini-splits and residential replacements, start with the power source you can actually use, then pick the pump—not just the biggest CFM number.

Our corded starting point is the Fieldpiece VP67. Choose NAVAC’s NP4DLM when an outlet is the nuisance. Yellow Jacket’s 93760 brings selectable voltage and an isolation valve; CPS’s VPS6DU brings a sealed start relay and ignition-proof switch; NAVAC’s NP5DP2 is a straightforward 5 CFM corded option.

Quick picks: which pump belongs in your install kit?

Your setup Our pick Why it fits
Corded residential work, with frequent oil changes Fieldpiece VP67 6 CFM and RunQuick oil changes while running
Mini-split work away from a convenient outlet NAVAC NP4DLM kit 4 CFM, an included battery/charger and a carry bag
A corded pump for different supply voltages Yellow Jacket SuperEvac PLUS II 93760 Selectable voltage, 6 CFM and an isolation valve
A sparkless 6 CFM setup CPS VPS6DU Sealed start relay, ignition-proof switch and maker-listed A2L use
A simple 5 CFM corded setup NAVAC NP5DP2 Dual-stage pump, gas ballast, oil-mist filter and lifting hook

Compare the maker specifications

Pump Flow Published pump vacuum rating Power Maker-listed weight A2L wording
Fieldpiece VP67 6 CFM 15 microns at input ports 120V/60Hz AC 29 lb empty A2L certified
NAVAC NP4DLM 4 CFM 15 microns ultimate 18V, 9Ah NBP2 battery 15.4 lb with battery, current product page A2L compatible
Yellow Jacket 93760 PLUS II 6 CFM 15 microns field blankoff Selectable 100–127V / 220–240V, 50–60Hz; factory 115V 25.9 lb net Designed for A2L; non-sparking switch
CPS VPS6DU 6 CFM at 60Hz 10 microns ultimate 115V/60Hz 22.5 lb A2L use; ignition-proof design
NAVAC NP5DP2 5 CFM 15 microns ultimate 115V/60Hz AC 24.3 lb A2L compatible

Weights retain each maker’s stated basis. The NP4DLM figure is from its current page and dedicated sheet; an older combined NAVAC manual lists a different figure. Sources: Fieldpiece manual, NAVAC NP4DLM, Yellow Jacket specification table, CPS VPS6DU and NAVAC NP5DP2.

Fieldpiece VP67: the corded all-rounder

Why you’ll like it: RunQuick lets you change the oil while the pump is running, with Fieldpiece quoting a 20-second change. The backlit reservoir puts the oil condition in view, and four inlet ports—one ¼-inch, two ⅜-inch and one ½-inch—give you room to arrange the evacuation hoses.

The VP67 is a two-stage, 6 CFM pump with a ½ HP AC motor. It’s the straightforward pick for a shop with power at the install and a habit of changing dirty oil promptly. The current product is A2L certified. Fieldpiece VP67 specifications and RunQuick.

Good to know: VP55 and VP85 are older models. Fieldpiece identifies VP67 as the VP55 replacement and VP87 as the VP85 replacement; shop by the exact current model rather than borrowing the old pump’s specifications. Fieldpiece model replacements.

Why you’ll like it: The 18V pump goes where the outlet doesn’t. NAVAC supplies the NP4DLM kit with its NBP2 9Ah battery, NC2 charger and carry bag, and publishes up to one hour of continuous runtime. It has an isolation valve, backflow-prevention check valve and gas ballast, with 4 CFM flow and a 15-micron ultimate rating.

The dedicated specification sheet and current product page put it at 15.4 lb with battery. The sheet also labels it A2L compatible. NAVAC NP4DLM specification sheet.

Good to know: The kit includes an oil dispenser, but oil is not supplied. The NAPS1 power-supply adapter is a separate accessory. NP4DLM kit contents and power options.

Yellow Jacket 93760: selectable voltage and tidy oil handling

Why you’ll like it: The SuperEvac PLUS II combines a brushless motor with an isolation valve for oil changes without losing the system vacuum. A large drain, angled sump and wide oil-fill opening make oil service part of the design, while the locking power connection keeps the cord attached.

Choose 93760 for the 6 CFM version. Its specification sheet lists selectable 100–127V/220–240V, 50–60Hz operation, factory set to 115V, plus a 15-micron field blankoff and 25.9 lb net weight. SuperEvac PLUS II specifications.

Good to know: Buy the PLUS II model number you need. Yellow Jacket specifically lists an A2L non-sparking switch on this family; its other SuperEvac generations and international part numbers are separate choices. PLUS II features and model list.

CPS VPS6DU: the sparkless six-CFM option

Why you’ll like it: CPS describes a sealed start relay, ignition-proof on/off switch and an ANSI ignition-proof design, and explicitly includes A2L systems in the feature list. It gives you 6 CFM at 60Hz, a published 10-micron ultimate vacuum and a 22.5 lb pump.

The large oil sight glass, gas ballast and oil-mist exhaust cap are practical day-to-day details. This is a 115V/60Hz corded unit with 16 oz oil capacity. CPS VPS6DU features and specifications.

Good to know: The letters matter: VPS6DU is the model here. A VP6D or VP6S listing is a different pump.

Why you’ll like it: The NP5DP2 pairs a two-stage design with forced oil circulation, a gas ballast and an oil-mist filter. Its lifting hook is useful when the kit has to travel above ground level, and the three inlet sizes fit different evacuation-hose setups.

NAVAC lists 5 CFM, a 15-micron ultimate vacuum, 24.3 lb weight and 115V/60Hz AC power. It is specifically an A2L-compatible model. NP5DP2 specifications.

Good to know: This is NP5DP2, not the older NP5DP. Its 17 oz oil capacity belongs on the van’s consumables list.

Buy the micron gauge with the pump

A pump’s CFM rating describes flow; its ultimate-vacuum figure describes what it can pull at its inlet under the maker’s conditions. For the job, put an electronic micron gauge at the system and record the result there against the appliance’s specified evacuation and hold criteria. Fieldpiece’s manual covers gauge placement, oil changes and the vacuum-isolation test. Fieldpiece evacuation and gauge guidance.

Use our digital manifold gauges guide to sort manifold kits from separate vacuum probes. A hose-free pressure/temperature probe kit and a dedicated micron gauge do different jobs. The refrigerant leak-detector guide covers the other part of the service kit.

For A2L work, get the handling training for the refrigerant and equipment you’re servicing; AHRI’s A2L resources point to training and safe-handling material.

Keep the vacuum and decay result with the install

The useful handoff is a job record the next tech can read. Save the equipment model/serial, refrigerant, pump and gauge used, achieved system vacuum, isolation start reading, elapsed hold time and final reading. Add a gauge photo or instrument report with the appliance’s target and the actual result.

A simple note template:

  • Equipment / refrigerant: [model, serial, refrigerant]
  • Evacuation: [pump, gauge, measured system microns]
  • Hold: [start reading, elapsed time, end reading]
  • Acceptance criterion: [appliance instruction and result]
  • Evidence / follow-up: [photo or report, technician, action needed]

Use Jobber for the install handover: keep the evacuation record and supporting files with the customer’s work.

In Jobber, add the readings and photos/files to the job’s internal notes. Keep the result beside the customer’s service history rather than in a separate phone gallery. Jobber notes and attachments.

HCP alternative: use the job’s private notes for the measurements, then attach the supporting photo/document when sharing the result with the customer. HCP private notes and customer attachments explain those two paths.

Use the field-service app you already run. The pump does the evacuation; the job record keeps the readings, photos and next action together. For a smaller shop choosing that app, start with our HVAC software checklist.

Removing the charge before repair? Our refrigerant recovery-machine guide covers A2L-compatible picks, cylinder kits and the recovered-weight job note.

Build the hold record into your workflow with our Jobber vs HCP job-form templates, including an HVAC install and commissioning record.

Pair the kit with a refrigerant charging scale to weigh the cylinder and save the measured amount with the job.

For the gauge and the timed hold record, use our HVAC micron-gauge guide: low-band accuracy, system-side placement and a named equipment-manual decay checklist.

Build the connection path around the pump with our core-removal tools and vacuum-hose guide: service-port sizes, hose bore and a maker-sourced hook-up order.

Sources

Where these facts come from.

Build your shortlist

Example equipment to compare

Find the listed models below.

As an Amazon Associate I earn from qualifying purchases.

Best corded residential all-rounder

Fieldpiece VP67 6 CFM RunQuick vacuum pump

RunQuick oil changes and four inlet ports make the 6 CFM A2L-certified VP67 a practical residential-install pump.

Check price on Amazon →

Best cordless mini-split setup

NAVAC NP4DLM 4 CFM cordless vacuum pump kit

An 18V battery-powered pump avoids hunting for an outlet while its isolation valve and gas ballast support evacuation work.

Check price on Amazon →

Best selectable-voltage pump

Yellow Jacket SuperEvac PLUS II 93760 6 CFM pump

A brushless motor, A2L non-sparking switch and isolation valve put the 6 CFM PLUS II in a versatile corded setup.

Check price on Amazon →

Best sparkless 6 CFM pick

CPS VPS6DU Pro-Set 6 CFM sparkless vacuum pump

CPS specifies an ignition-proof switch and sealed start relay, with 6 CFM airflow in a 22.5 lb pump.

Check price on Amazon →

Best straightforward 5 CFM corded setup

NAVAC NP5DP2 5 CFM A2L vacuum pump

A dual-stage pump with gas ballast, oil-mist filter and lifting hook covers a simple corded evacuation setup.

Check price on Amazon →

Explore an option for your shop

Start with the tool that fixes your bottleneck.

Start with Fieldpiece VP67 for a corded residential setup with RunQuick oil changes. Choose NAVAC NP4DLM for cordless mini-split work, Yellow Jacket 93760 for selectable voltage, CPS VPS6DU for a sparkless 6 CFM setup, or NAVAC NP5DP2 for a straightforward corded five-CFM pump. Pair the pump with a system-side micron gauge, then save the vacuum and hold result with the install.